Sustainable Data Center Cooling: CUE, Free Cooling, and ERE

By Julius Neudorfer - November 16, 2021

Sustainable Data Center Cooling: CUE, Free Cooling, and ERE

The entrance to the Nautilus Data Technologies facility in Stockton. (Photo: Nautilus Data)

LinkedinTwitterFacebookSubscribe
Mail

Last week in our special report series, we explored three external heat rejection systems. This week, in our final article in the series on sustainable data center cooling challenges, we’ll discuss three more external heat rejection systems. 

Carbon Usage Effectiveness

Carbon Usage Effectiveness (CUE) is another essential sustainability metric directly tied to the source of energy generation.

It is expressed as CUE Source – Based on the annualized carbon emitted by the energy source (power generation), expressed as kilograms of carbon emitted per kWh of IT Energy generated. (kg/IT kWh).

The EPA’s Emissions & Generation Resource Integrated Database (eGRID) website has a tool that allows users to enter their zip codes (or select a region) to view their power profiles.

Sustainable Data Center

Source: EPA

Sustainable Data Center

Source: EPA

Free Cooling

Free cooling is typically referred to as any type of cooling system which reduces or eliminates the need for mechanical cooling (i.e., compressor based). This can include direct or indirect air-side economizers, as well as water-side economizers. The water-side economizer is generally based on a heat exchanger which allows cooling tower water to reduce the load on water-cooled chillers during cooler weather. All of these systems generally save a percentage of mechanical cooling energy during cooler weather. Overall, free cooling is more effective in colder climates, for both air-side and water- side economizers. There are many variations and combinations of methodologies that can be combined to maximize energy effectiveness and optimize water usage over the seasons.

While water in itself is not energy, it requires energy to process and deliver clean water. This is often overlooked or ignored. However, as water shortages increase, this is being addressed in the California Energy Code: Codes and Standards Enhancement (CASE) Initiative 2022 – “Title 24 2022 Nonresidential Computer Room Efficiency” (CA-Title 24), as “Embedded Electricity in Water.”

Alternately, waste heat can also be rejected into bodies of water, such as lakes and rivers or even the ocean. In many cases, the temperature ranges of those bodies of water are such that they can be used all year round to cool data centers without the need for mechanical cooling, a significant energy savings. These savings can also reduce or eliminate consumption of source water, as well as reducing fossil fuels used in non-renewable power generation.

Energy Reuse Effectiveness

The total waste heat generated by an air-cooled or a liquid-cooled data center is virtually the same for a given amount of total energy consumed. Clearly, a lower PUE will reduce the total energy consumed for a given IT load. While end-to-end thermal management typically refers to “chip-to-atmosphere” heat rejection, it is still just waste heat. One of the long-term sustainability goals is being able to recover and reuse waste heat.

Sustainable Data CenterThe Green Grid introduced the energy reuse effectiveness (ERE) metric in 2011, energy reuse factor (ERF), with relatively little impact. This was primarily because waste heat from air-cooled ITE being rejected is more difficult to recover effectively.

Liquid Cooling provides a pathway to more effective opportunities for energy reuse and recovery. Its higher fluid operating and return temperatures improve the ability to recover a portion of the waste heat energy. However the challenges are multi- dimensional, but as time progresses the interest, technology improvements and cost effectiveness will continue to drive this initiative. While higher power densities can create cooling challenges, it also offers multiple benefits and opportunities to improve overall energy efficiency, IT performance, and sustainability. However, the challenges are multi-dimensional, but the interest, technology improvements, and cost-effectiveness will continue to drive this initiative as time progresses.

Download the full report, “Sustainably Meeting High Density Cooling Challenges: When, Where, and How,” courtesy of Nautilus Data Technologies for exclusive look at the Nautilus water-cooled data center.

LinkedinTwitterFacebookSubscribe
Mail

Tagged With: Data Center Cooling, data center sustainability, high density data centers, Nautilus Data

Newsletters

Stay informed: Get our weekly updates!

Are you a new reader? Follow Data Center Frontier on Twitter or Facebook.
  • Facebook
  • Instagram
  • LinkedIn
  • Pinterest
  • Twitter

Voices of the Industry

Understanding the Differences Between 5 Common Types of Data Centers

Understanding the Differences Between 5 Common Types of Data Centers No two are data centers are alike when it comes to design or the applications and data they support with their networking, compute and storage infrastructure. Shad Secrist of Belden outlines the differences between 5 of the most common types of data centers including edge, colocation and hyperscale.

White Papers

400 Gigabit

The Journey to 400/800G has Begun

While 400 Gigabit speeds are still several years out for enterprise data centers, industry standards and active equipment for 400 Gigabit applications are already available and being deployed by hyperscale cloud providers. A new white paper from Siemon explores the factors data centers should consider when determining which path to 400 Gigabit they should take.

Get this PDF emailed to you.

We always respect your privacy and we never sell or rent our list to third parties. By downloading this White Paper you are agreeing to our terms of service. You can opt out at any time.

DCF Spotlight

Data center modules on display at the recent Edge Congress conference in Austin, Texas. (Photo: Rich Miller)

Edge Computing is Poised to Remake the Data Center Landscape

Data center leaders are investing in edge computing and edge solutions and actively looking at new ways to deploy edge capacity to support evolving business and user requirements.

An aerial view of major facilities in Data Center Alley in Ashburn, Virginia. (Image: Loudoun County)

Northern Virginia Data Center Market: The Focal Point for Cloud Growth

The Northern Virginia data center market is seeing a surge in supply and an even bigger surge in demand. Data Center Frontier explores trends, stats and future expectations for the No. 1 data center market in the country.

See More Spotlight Features

Newsletters

Get the Latest News from Data Center Frontier

Job Listings

RSS Job Openings | Pkaza Critical Facilities Recruiting

  • Critical Power Energy Manager - Data Center Development - Ashburn, VA
  • Site Development Manager - Data Center - Ashburn, VA
  • Data Center Facility Operations Director - Chicago, IL
  • Electrical Engineer - Senior - Dallas, TX
  • Mechanical Commissioning Engineer - Calgary, Alberta

See More Jobs

Data Center 101

Data Center 101: Mastering the Basics of the Data Center Industry

Data Center 101: Mastering the Basics of the Data Center Industry

Data Center Frontier, in partnership with Open Spectrum, brings our readers a series that provides an introductory guidebook to the ins and outs of the data center and colocation industry. Think power systems, cooling, solutions, data center contracts and more. The Data Center 101 Special Report series is directed to those new to the industry, or those of our readers who need to brush up on the basics.

  • Data Center Power
  • Data Center Cooling
  • Strategies for Data Center Location
  • Data Center Pricing Negotiating
  • Cloud Computing

See More Data center 101 Topics

About Us

Charting the future of data centers and cloud computing. We write about what’s next for the Internet, and the innovations that will take us there. We tell the story of the digital economy through the data center facilities that power cloud computing and the people who build them. Read more ...
  • Facebook
  • LinkedIn
  • Pinterest
  • Twitter

About Our Founder

Data Center Frontier is edited by Rich Miller, the data center industry’s most experienced journalist. For more than 20 years, Rich has profiled the key role played by data centers in the Internet revolution. Meet the DCF team.

TOPICS

  • 5G Wireless
  • Cloud
  • Colo
  • Connected Cars
  • Cooling
  • Cornerstone
  • Coronavirus
  • Design
  • Edge Computing
  • Energy
  • Executive Roundtable
  • Featured
  • Finance
  • Hyperscale
  • Interconnection
  • Internet of Things
  • Machine Learning
  • Network
  • Podcast
  • Servers
  • Site Selection
  • Social Business
  • Special Reports
  • Storage
  • Sustainability
  • Videos
  • Virtual Reality
  • Voices of the Industry
  • Webinar
  • White Paper

Copyright Data Center Frontier LLC © 2022