Lithium-Ion Batteries Offer Energy Storage TCO Savings

Aug. 21, 2018
Our second entry in a four-part Data Center Frontier Special Report Series that explores the future of lithium-ion batteries and their impact on energy storage, moves on to explore how lithium-ion batteries can lead to TCO savings for energy storage. 

Our first entry in the four-part Data Center Frontier Special Report Series  that explores the future of lithium-ion batteries and their impact on energy storage, offered a comparison off the capabilities and characteristics of lead acid versus lithium-ion batteries. The series moves on in this post to explore how lithium-ion batteries can lead to energy storage TCO savings. 

Download the Full Report.

Today, for typical UPS applications, the initial capital expense of lithium-ion batteries is only 1.4 times more than lead acid batteries. But lithium-ion batteries will provide a 10-year TCO savings of 10%- 30%. The advantages of lithium-ion batteries include:

Reliability and Availability

The manufacturing methods used to produce lithium-ion batteries vs lead-acid cells results in a much lower failure rate. With a longer lifespan and lower maintenance requirements, the failure of lithium-ion batteries in UPS applications is almost non-existent.

Depending on the chemistry used, lithium-ion batteries can have a lifespan of up to 15 years. This offers a huge savings in replacement costs over lead acid batteries, since lithium-ion batteries don’t have to be replaced every 3-4 years.

Also, lithium-ion batteries typically have a longer cycle life than lead acid batteries. For example, a lead acid battery usually gives you 200 discharge cycles, meaning you can deplete the battery’s energy (watt-hours) to 50% of its rating, and then recharge it back to 100% power a total of 200 times before the battery dies. But lithium batteries provide 500- 7000 discharge cycles (depending on chemistry used) before you have to replace the battery. Additionally, lithium-ion batteries have a lower self-discharge rate, or slow discharge of the battery when not in use, which gives them a longer shelf life.

Lower Weight

Lithium-ion batteries weigh about a third less than lead acid batteries. This saves money on construction costs, since you don’t need to reinforce floors to handle more weight. It also saves money in shipping and transportation, since you can ship the same energy capacity in lithium-ion batteries at a lower cost.

Smaller Footprint

Lithium-ion cabinets are typically one-half the size of lead acid cabinets, providing a 50% savings in floor space for the same amount of energy. This allows you re-design your data center to increase available floor space for IT systems. It can also provide savings in construction costs for new data centers, since you can build smaller rooms to hold lithium-ion cabinets for UPS energy storage purposes.

Equivalent Energy 

Lithium batteries have a higher energy density (Wh/kg, or watt hours per kilogram) and power density (W/kg, or watts per kilogram). This is why lithium batteries offer the same amount of energy as lead acid batteries at a smaller size and lower weight.

Higher Ambient Temperatures

Lithium batteries can operate at temperatures of 86°F (30°C), almost 10 degrees higher than lead acid batteries. This allows you to increase room temperatures in the data center, which reduces energy used for cooling, and lowers cooling costs, and as a result energy storage TCO.  Also, li-ion batteries are less sensitive to temperature changes, and temperature spikes will not shorten the battery’s useful life.

Less Maintenance

Lithium batteries come with a built-in battery management system (BMS), which provides automatic status and fault monitoring, cell balancing, power optimization, and external communications. The BMS makes it easier for facility engineers to monitor a battery’s run-time and health, reducing labor and maintenance costs, and significantly reducing the risk of a surprise battery string failure.

Faster Recharge

Lithium-ion batteries fully recharge in about two hours, while lead acid batteries fully recharge in about 24 hours. The faster recharge time means li-ion batteries are better able to handle multiple outage scenarios. (For example, if you have several outages in a 24-hour period, the lithium battery can recharge faster to provide full UPS ride-through time for each outage.)

Environmental Advantages

Lithium batteries have one-third the carbon footprint of lead acid batteries, and are not as environmentally invasive.

In the coming weeks, the special report series will also cover the following topics:

Download the full report, “Why Lithium-Ion Batteries are the Future of UPS Energy Storage for Data Centers and Colocation Facilities,” courtesy of Liion, to lean more about the potential of lithium-ion batteries. 

About the Author

Robert Lindsay

Robert S. Lindsay is a Seattle-based writer who writes for and about the data center industry. He can be reached at robertlindsay at strategicwordsmith.biz.

Sponsored Recommendations

How Deep Does Electrical Conduit Need to Be Buried?

In industrial and commercial settings conduit burial depth can impact system performance, maintenance requirements, and overall project costs.

Understanding Fiberglass Conduit: A Comprehensive Guide

RTRC (Reinforced Thermosetting Resin Conduit) is an electrical conduit material commonly used by industrial engineers and contractors.

NECA Manual of Labor Rates Chart

See how Champion Fiberglass compares to PVC, GRC and PVC-coated steel in installation.

Electrical Conduit Cost Savings: A Must-Have Guide for Engineers & Contractors

To help identify cost savings that don’t cut corners on quality, Champion Fiberglass developed a free resource for engineers and contractors.

Courtesy of Park Place Technologies
Courtesy of Park Place Technologies

Immersion or Direct-to-Chip: A Comparison of the Most Common Liquid Cooling Technologies

Which liquid cooling technology is right for your organization? Chris Carreiro, Chief Technology Officer at Park Place Technologies, compares the most common liquid cooling technologies...

White Papers

Get the full report

Hybrid Cloud

Nov. 14, 2021
It’s not a matter of choosing or favoring either data center, cloud, or colocation, but selecting the most appropriate tool for the application, workload and desired outcome. ...