Beyond PUE: Challenges in Cooling High Density Data Centers

Nov. 4, 2021
As important as PUE was in raising energy awareness, it is only a part of more in-depth conversations about data center sustainability. A new special report from Nautilus Data Technologies and Data Center Frontier looks at how to sustainably meet high density cooling challenges.

Last week we launched a special report series on how to sustainably meet high density data center cooling challenges. This week, we’ll take a look at three more IT equipment heat removal challenges. 

IT Equipment Heat Removal Challenges, Part 2

Liquid Cooling

Liquid Cooling (LC) has become a bit of a catchall term that encompasses many different technologies and methodologies to transfer heat from the IT equipment to the environment. While this is a highly complex subject, for purposes of this discussion it is simplified into several major categories, described in the table below.

For additional details and references for liquid cooling see: The Green Grid white paper WP#70 Liquid-Cooling-Technology-Update.

An ASHRAE 2021 white paper, Emergence and Expansion of Liquid Cooling in Mainstream Data Centers, focuses on the need for data centers to accommodate and adapt to rising power densities.

It also notes that while higher power processors are the primary thermal management challenge, higher density power levels due to an increase of memory DIMMs in new servers add to the load.
The white paper discusses a CPU roadmap moving from 120-200 watts to 600 watts per processor (CPU, GPU, etc.). This white paper reports these limitations and notes that “A fan power percentage of 10% to 20% is not uncommon for some of the denser air-cooled servers.”

The Green Grid Metric – Power Utilization Effectiveness

The Green Grid (TGG) created the Power Utilization Effectiveness (PUE) metric in 2007. Since then, it has the most globally recognized facility efficiency metric that helped drive down PUE for “traditional” enterprise and colocation MTDC data centers (from approximately 2.0 in 2010 to 1.4 or less in 2020). In 2016 the International Standards Organization (ISO) adopted PUE and other TGG metrics as Key Performance Indicators (listed ISO/IEC 30134 KPI series). When examining PUE as an energy efficiency comparison yardstick, it is one-dimensional. Nonetheless, its underlying simplicity allowed data center operators to easily calculate (or estimate) a facility’s PUE, which drove its widespread adoption.

Moving beyond PUE

For many years, the data center ecosphere quoted and referenced PUE as the primary element of their “green” mantra. As important as PUE was in raising energy awareness, it is only a part of more in-depth conversations about data center sustainability. The current focus is now on decarbonizing and moving to 100% renewable energy sources. While renewable energy is clearly an important factor, many data centers use water as part of the external heat rejection process, regardless of the energy source.

Download the full report, Sustainably Meeting High Density Cooling Challenges: When, Where, and How,” courtesy of Nautilus Data Technologies to learn more about high density data center cooling. In our next article, we’ll look at three external heat rejection systems. Catch up on the previous article in the series here.

About the Author

Julius Neudorfer

Julius Neudorfer is the CTO and founder of North American Access Technologies, Inc. (NAAT). NAAT has been designing and implementing Data Center Infrastructure and related technology projects for over 25 years. He also developed and holds a patent for high-density cooling. Julius is a member of AFCOM, ASHRAE, IEEE and The Green Grid. Julius has written numerous articles and whitepapers for various IT and Data Center publications and has delivered seminars and webinars on data center power, cooling and energy efficiency.

Sponsored Recommendations

Guide to Environmental Sustainability Metrics for Data Centers

Unlock the power of Environmental, Social, and Governance (ESG) reporting in the data center industry with our comprehensive guide, proposing 28 key metrics across five categories...

The AI Disruption: Challenges and Guidance for Data Center Design

From large training clusters to small edge inference servers, AI is becoming a larger percentage of data center workloads. Learn more.

A better approach to boost data center capacity – Supply capacity agreements

Explore a transformative approach to data center capacity planning with insights on supply capacity agreements, addressing the impact of COVID-19, the AI race, and the evolving...

How Modernizing Aging Data Center Infrastructure Improves Sustainability

Explore the path to improved sustainability in data centers by modernizing aging infrastructure, uncovering challenges, three effective approaches, and specific examples outlined...

Julia Ardaran / Shutterstock.com

Beyond Hyperscale: Quantum Frederick's Vision for Sustainable Data Center Development

Scott Noteboom, CTO of Quantum Loophole, explains how Quantum Frederick created the first carbon neutral industrial zone.

White Papers

DCF_KohlerWPCover_2021-12-08_8-46-39

Data Center Generator Maintenance

Dec. 10, 2021
A new white paper from Kohler Power Systems explains the feasibility and benefits of no-load exercising for diesel generator operators.