• About Us
  • Partnership Opportunities
  • Privacy Policy

Data Center Frontier

Charting the future of data centers and cloud computing.

  • Cloud
    • Hyperscale
  • Colo
    • Site Selection
    • Interconnection
  • Energy
    • Sustainability
  • Cooling
  • Technology
    • Internet of Things
    • AI & Machine Learning
    • Edge Computing
    • Virtual Reality
    • Autonomous Cars
    • 5G Wireless
    • Satellites
  • Design
    • Servers
    • Storage
    • Network
  • Voices
  • Podcast
  • White Papers
  • Resources
    • COVID-19
    • Events
    • Newsletter
    • Companies
    • Data Center 101
  • Jobs
You are here: Home / Voices of the Industry / The Future of Fire Protection for Battery Energy Storage Systems

The Future of Fire Protection for Battery Energy Storage Systems

By Voices of the Industry - February 18, 2022

The Future of Fire Protection for Battery Energy Storage Systems

Conceptual image of a modern battery energy storage system with wind turbines and solar panel power plants in background. (Source: AdobeStock, courtesy of Viking Integrated Safety)

LinkedinTwitterFacebookSubscribe
Mail

In this edition of Voices of the Industry, Steven Joseph, Director of Business Development at Viking Integrated Safety, explores options for reliable fire protection for battery energy storage systems.  

Battery Energy Storage

Steven Joseph is the of Director of Business Development at Viking Integrated Safety

Battery energy storage systems (BESS) are reservoirs for electrical energy, typically generated from renewable sources like wind and solar farms, or from the existing power grid. They buffer the energy for use when demand rises, or emergencies occur. Increasingly, BESS are used as emergency power systems (EPS) for data centers, replacing diesel- or gas-based systems. Analysts expect the BESS market to expand to $26B USD by 2026, with 97.8% of systems using lithium-ion (Li-ion) batteries.

Li-ion batteries deliver good energy density in a small, cost-effective footprint — but that comes with a risk. When a Li-ion cell fails or is subjected to abuse, a potentially catastrophic event known as thermal runaway can occur, where chemical energy is converted to thermal energy. Once an ignition threshold is reached the process will continue to propagate, or spread, from cell to cell consuming the BESS, and where adjacent structures are present, the potential for a facility-wide disaster.

Stages of a BESS Fire

BESS fires tend to follow a familiar pattern of stages:

Stage 1) A manufacturing defect or mechanical, electrical, or thermal abuse initiates a thermal reaction in a battery cell.

Stage 2) The damaged cell begins to overheat and vent traces of CO2, Volatile Organic Compounds (VOC), and potentially other compositions of vent-gasses, depending on battery chemistry. Incipient smoke may also be present as a result of the thermal event. Intervention is essential at this stage to mitigate or prevent thermal runaway.

Stage 3) As thermal runaway begins it cannot be stopped, but propagation can be mitigated.

Stage 4) An explosion and/or fire that can consume the BESS and spread to adjacent units.

While investigating this fire threat, NFPA Fire Protection Research Foundation Report confirmed that Li-ion batteries use dissolved lithium salts (LiPF6) rather than free lithium metal, so that water can be used as an extinguishing agent. Of course, the high heat could produce a situation where a steam explosion could occur compounding the threat. Water may not be able to reach concealed or enclosed cells and could also do extensive damage to electrical and mechanical systems not involved in the incident. Further, water may not be readily available for remote locations.

Very Early Warning Sensors for Threat Detection

Fortunately, there are technologies and techniques that can mitigate or avoid battery thermal runaway if threat warning signs are detected early. Effective mitigation techniques can be realized by design, monitoring, and active control using early warning smart sensors and appropriate suppression technologies at the right stage of threat development and before propagation. Sensors recommended for a BESS include:

  • Battery Management Systems (BMS) monitor the temperature, voltage, and impedance of individual batteries, and alert when limits are breached.
  • Power Quality Sensors can monitor for electrical abuse by analyzing and translating power quality in simple and actionable information.
  • Thermal Imaging IR Sensors can monitor battery surface temperatures at up to 9600 discrete points every 2 seconds, highlighting potential hotspots. They can also be used to monitor other equipment like PDUs, CPUs, fans, and other mechanical subsystems
  • Typical coolants in a Li-ion BESS consist of 50% ethylene glycol and 50% water. With Coolant & Water sensors, leaks can be detected and immediate action taken to limit a disaster like Victorian Big Battery Fire in Australia.
  • Refrigerant (R-134a) Gas sensors can detect leaks from a failing cooling system.
  • Shock & Vibration sensors can monitor another root cause of catastrophic battery failures: mechanical abuse. By recording vibrations multiple times per second, potential mechanical abuse can be detected.

A New Sensor for Early Threat Detection

The authors of a study titled Detection of Li-ion battery failure and venting with Carbon Dioxide sensors, concluded that “CO2 and VOC are found in high concentrations in vent-gas from all thermal runaway experiments. Both gas species exist in the first vent-gas, and enable cell leakage detection, so these two gas species are considered good for detection purposes.” VOCs are carbon-based chemicals, like methyl ethyl carbonate (C4H8O3), with propane used as an analog for detection.

As soon as the sensors (or a combination of sensor alarms) detect a threat (Stages 1 & 2), the BESS should be powered down and an automatic suppression system triggered. As mentioned, water should be avoided at these early stages, as it does not reliably reach hidden or obscured fires and could potentially damage electrical and mechanical systems.

Appropriate Suppression Can Prevent Threat Propagation

A fire-suppression system employing inert gas can be effective by both depleting oxygen in the room and extracting the heat from a fire. Inert gases like argon, carbon dioxide, and nitrogen are electrically nonconductive and leave no residue to clean up. Suppression can be directed to specific threat areas or in a total flooding application where the agent fills the entire container or room. Even if a non-battery component of the BESS is involved in a fire, this method can extinguish the fire without causing water damage or requiring post-action cleanup.

Rapidly flooding the BESS with the extinguishing agent prevents the formation of large amounts of an explosive electrolyte-oxygen mixture, reducing a thermal runaway event, and inhibiting the spread to adjacent battery cells. This eliminates secondary fires and the potential for reignition, as the inert gas can remain for an extended period when the system is integrated with the ventilation system.

What is the most suitable extinguishing agent? Chemical extinguishing agents cannot be used in this application scenario because hazardous decomposition products may form, or extended discharge may be necessary. Potential alternatives are three natural extinguishing gases: nitrogen (N2), carbon dioxide (CO2) and argon (Ar). Argon is a single atom molecule and doesn’t react with any element on the periodic table. It does not decompose in high-temperature fire situations, its safe for equipment present and suitable for extinguishing class A, B, C and D fires making it widely compatible with varying battery chemistries. For these reasons, Argon is a suitable extinguishing agent for Li-ion battery storage systems, delivering excellent results.

With renewable energy sources powering the future, the need for reliable and cost-effective energy storage is essential. In the lifetime of any critical infrastructure system like a BESS, reliable fire prevention is a key to lowering total operating costs (TOC) over the lifetime of the system. Very early warning sensors combined with appropriate and effective clean suppression systems can serve that role, detecting threats early and mitigating propagation before disasters result.
Steven Joseph is the of Director of Business Development at Viking Integrated Safety, and has 30+ years in the design and deployment of fire protection solutions for critical infrastructure. Viking Integrated Safety leverages the broad range of Minimax Viking products to provide fully integrated, pre-engineered fire prevention solutions for targeted applications. These solutions combine technologies from industrial IoT smart sensors, flame/heat/smoke/gas detectors, alarm & control panels, notification & A/V appliances, and extinguishment systems into integrated, reliable, and cost-effective kits.

LinkedinTwitterFacebookSubscribe
Mail

Tagged With: data center fire suppression, Energy, Storage, Viking Integrated Safety

Newsletters

Stay informed: Get our weekly updates!

Are you a new reader? Follow Data Center Frontier on Twitter or Facebook.
voices@richmiller.biz'

About Voices of the Industry

Our Voice of the Industry feature showcases guest articles on thought leadership from sponsors of Data Center Frontier. For more information, see our Voices of the Industry description and guidelines..

  • Facebook
  • Instagram
  • LinkedIn
  • Pinterest
  • Twitter

Voices of the Industry

Mitigate Risk, Improve Performance and Decrease Operating Expenses through Data Center Self-Performance

Mitigate Risk, Improve Performance and Decrease Operating Expenses through Data Center Self-Performance If a vendor conducts the actual work in your data center, then you or your operator aren’t maximizing your current operating resources and are experiencing incremental cost and risk. Chad Giddings of BCS Data Center Operations, explains the importance of your data center provider having a high-degree of self-performance.

White Papers

colocation data center

Top Factors to Consider when Assessing a Colocation Data Center Facility

Colocation data centers have become popular alternatives to proprietary facilities for several key reasons, including core competency, access to cost-efficient expertise, flexability and scalability, and more. Get the new white paper from Sabey Data Centers that explores in details factors to consider when choosing a colocation data center facility and provider. 

Get this PDF emailed to you.

We always respect your privacy and we never sell or rent our list to third parties. By downloading this White Paper you are agreeing to our terms of service. You can opt out at any time.

DCF Spotlight

Data center modules on display at the recent Edge Congress conference in Austin, Texas. (Photo: Rich Miller)

Edge Computing is Poised to Remake the Data Center Landscape

Data center leaders are investing in edge computing and edge solutions and actively looking at new ways to deploy edge capacity to support evolving business and user requirements.

An aerial view of major facilities in Data Center Alley in Ashburn, Virginia. (Image: Loudoun County)

Northern Virginia Data Center Market: The Focal Point for Cloud Growth

The Northern Virginia data center market is seeing a surge in supply and an even bigger surge in demand. Data Center Frontier explores trends, stats and future expectations for the No. 1 data center market in the country.

See More Spotlight Features

Newsletters

Get the Latest News from Data Center Frontier

Job Listings

RSS Job Openings | Pkaza Critical Facilities Recruiting

  • Electrical Commissioning Engineer - Los Angeles, CA
  • Data Center Construction Project Manager - Ashburn, VA
  • Critical Power Energy Manager - Data Center Development - Dallas, TX
  • Data Center Facilities Operations VP - Seattle, WA
  • Senior Electrical Engineer - Data Center - Dallas, TX

See More Jobs

Data Center 101

Data Center 101: Mastering the Basics of the Data Center Industry

Data Center 101: Mastering the Basics of the Data Center Industry

Data Center Frontier, in partnership with Open Spectrum, brings our readers a series that provides an introductory guidebook to the ins and outs of the data center and colocation industry. Think power systems, cooling, solutions, data center contracts and more. The Data Center 101 Special Report series is directed to those new to the industry, or those of our readers who need to brush up on the basics.

  • Data Center Power
  • Data Center Cooling
  • Strategies for Data Center Location
  • Data Center Pricing Negotiating
  • Cloud Computing

See More Data center 101 Topics

About Us

Charting the future of data centers and cloud computing. We write about what’s next for the Internet, and the innovations that will take us there. We tell the story of the digital economy through the data center facilities that power cloud computing and the people who build them. Read more ...
  • Facebook
  • LinkedIn
  • Pinterest
  • Twitter

About Our Founder

Data Center Frontier is edited by Rich Miller, the data center industry’s most experienced journalist. For more than 20 years, Rich has profiled the key role played by data centers in the Internet revolution. Meet the DCF team.

TOPICS

  • 5G Wireless
  • Cloud
  • Colo
  • Connected Cars
  • Cooling
  • Cornerstone
  • Coronavirus
  • Design
  • Edge Computing
  • Energy
  • Executive Roundtable
  • Featured
  • Finance
  • Hyperscale
  • Interconnection
  • Internet of Things
  • Machine Learning
  • Network
  • Podcast
  • Servers
  • Site Selection
  • Social Business
  • Special Reports
  • Storage
  • Sustainability
  • Videos
  • Virtual Reality
  • Voices of the Industry
  • Webinar
  • White Paper

Copyright Endeavor Business Media© 2022