Follow the Network: Connectivity and Data Center Site Selection

Oct. 16, 2020
Data centers require reliable, robust and scalable network connections. These needs should be considered early in the planning process. A new Data Center Frontier report series continues to explore the ins and outs of data center site selection.

Stack Infrastructure and Data Center Frontier continue a new special report series by highlighting the role of network connections in data center site selection. 

Get the full report.

Network latency is bad for business and getting worse as customers grow increasingly intolerant of slow response times. The business impact can be substantial.

Data centers require reliable, robust and scalable network connections. These needs should be considered early in the planning process.

A data center may get better performance from interconnecting with a network dense facility 500 miles away than from a resource-starved one 150 miles away.

A common misconception is that latency is a function of the data center’s proximity to end-users. In fact, a more important factor is proximity to exchanges and cloud on-ramps. A data center may get better performance from interconnecting with a network dense facility 500 miles away than from a resource-starved one 150 miles away.

The bandwidth and latency needs of individual data centers vary by the type of traffic that traverses the network. For example, financial applications are likely to be more sensitive to latency issues than website hosting. Capacity and performance demands are also likely to change due to financial conditions, application availability needs and target markets. It is important to understand the nature of the traffic that will be passing over the network.

It’s also important to know what percentage of responses can be generated internally versus requiring queries over the public Internet.

For example, traditional OLTP workloads largely generate predictable north-south traffic between users and servers. With the growth of social media and mobile apps, those traffic patterns are more complex. A single query may now generate a significant amount of east-west traffic as user demographics, browsing history and recent purchases are factored into the response as well as ad-serving choices generated by real-time auctions. Hyperscale applications are also increasingly making use of microservices, which can cause a single query to generate hundreds of downstream requests to other servers. The slowest microservice can drag down overall response times.

The availability of dark fiber is also a key concern because installing fiber is expensive and time-consuming. At the right scale, dark fiber allows for rapid and cost-effective deployment of network capacity, by adding new channels on the existing dark fiber in the ground. Installing fiber is an expensive proposition, so take the time to determine if there is dark fiber in the area and the cost of activating it.

Catch up on the first and second entry in the series. And stay tuned for more data center site selection information on stakeholders, preparing for the unexpected and more, in the coming weeks.

Get the new special report, “Five Things To Know About Data Center Site Selection, courtesy of Stack Infrastructure, to learn more about how to successfully approach the data center site selection process. 

About the Author

Paul Gillin

Paul Gillin is a speaker, writer and technology journalist who has written five books and more than 400 articles on the topic of social media and digital marketing. A technology journalist for 25 years, he has served as Enterprise Editor of the tech news site SiliconAngle since 2014. He was founding editor-in-chief of B2B technology publisher TechTarget, and served as editor-in-chief and executive editor of the technology weekly Computerworld.

Sponsored Recommendations

How Deep Does Electrical Conduit Need to Be Buried?

In industrial and commercial settings conduit burial depth can impact system performance, maintenance requirements, and overall project costs.

Understanding Fiberglass Conduit: A Comprehensive Guide

RTRC (Reinforced Thermosetting Resin Conduit) is an electrical conduit material commonly used by industrial engineers and contractors.

NECA Manual of Labor Rates Chart

See how Champion Fiberglass compares to PVC, GRC and PVC-coated steel in installation.

Electrical Conduit Cost Savings: A Must-Have Guide for Engineers & Contractors

To help identify cost savings that don’t cut corners on quality, Champion Fiberglass developed a free resource for engineers and contractors.

CoolIT Systems
Source: CoolIT Systems

Selecting the Right Coolant Distribution Unit for Your AI Data Center

Ian Reynolds, Senior Project Engineer with CoolIT Systems, outlines considerations for selecting the best CDU for your needs.

White Papers

Get the full report

Enhancing Resiliency For the Energy Transition

Nov. 14, 2021
This white paper from Enchanted Rock explores how dual purpose microgrids can offer resiliency and stability to the grid at large.